Customization: | Available |
---|---|
Type: | Copper Pipe |
Length: | 10mm-12000mm |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product Name |
ASTM B280 C10200/C12000/C12200 Copper Pipe For Air Conditioning and Refrigeration |
|
Size
|
Outside Diameter |
2-914mm |
Thickness |
1mm~220mm (Sch5X~Sch XXS) |
|
Max Length |
1-50m |
|
Usage |
Gas Industry, Oilfield, Thermal power, Oil industry, Shipbuilding, Petrochemical, Tanker, Nuclear , etc |
|
Surface |
Pickling and annealing,pickling and annealing+polishing+ EP(Electricity polish) |
|
End |
Plain, Beveled with caps |
|
Processing Service |
Bending, Decoiling, Welding, Punching, Cutting |
|
Standard |
GB/T 19849-2005, EN 1254-1, ASTM B88M, BS EN1254, DIN 2856, etc. |
|
Payment: |
L/C at sight, L/C 180 days, T/T, D/P, OA, Western Union, |
|
Port of Shipment |
Shanghai port in China |
Copper UNS C10200 Annealed Tube Applicable Specification
Form | Application | Specific Sub-Form | System | Standard |
---|---|---|---|---|
Seamless Condenser Tube & Ferrule Stock | Condenser Tube | ASME | SB111 | |
Pipe | Seamless | ASTM | B42 | |
ASTM | B698 | |||
ASME | SB42 | |||
Bus Bar | ASTM | B188 | ||
ASTM | B88M | |||
Tube, water | ASTM | B88 | ||
Tube | ASTM | B698 | ||
For Air Conditioning and Refrigeration Field Servi | SAE | J461 | ||
MILITARY | MIL-T-24107 | |||
ASTM | B75/B75M | |||
MILITARY | MIL-T-24107 | |||
ASTM | B716 | |||
ASTM | B395/B395M | |||
ASTM | B640 | |||
ASME | SB75 | |||
ASTM | B280 | |||
ASTM | B359/B359M | |||
ASME | SB395 | |||
SAE | J461 | |||
ASME | SB359 | |||
Bus Bar | ASTM | B188 | ||
SAE | J461 | |||
For Air Conditioning And Refrigeration Field Servi | SAE | J463 | ||
MILITARY | MIL-T-3235 | |||
Rectangular Waveguide | ASTM | B372 | ||
ASTM | B641 | |||
ASTM | B743 | |||
ASTM | B641 | |||
ASTM | B447 | |||
SAE | J463 | |||
Rectangular Waveguide | MILITARY | MIL-W-85 |
SIZE | Length | Thickness | Weight Per | Weight | Weight Per | No. of Tubes |
---|---|---|---|---|---|---|
3 MTR | Per MTR | Bundle | Per Bundle | |||
12MM | 3 MTR | 0.9 | 0.690 | 0.230 | 27.6 | 40 |
12MM | 3 MTR | 0.7 | 0.480 | 0.160 | 24 | 50 |
15MM | 3 MTR | 0.9 | 1.100 | 0.367 | 27.5 | 25 |
15MM | 3 MTR | 0.7 | 0.690 | 0.230 | 27.6 | 40 |
22MM | 3 MTR | 0.9 | 1.630 | 0.543 | 32.6 | 20 |
35MM | 3 MTR | 1.2 | 3.450 | 1.150 | 34.5 | 10 |
28MM | 3 MTR | 0.9 | 2.080 | 0.693 | 31.2 | 15 |
42MM | 3 MTR | 1.2 | 4.200 | 1.400 | 29.4 | 7 |
76MM | 3 MTR | 1.5 | 9.480 | 3.160 | 28.5 | 3 |
54MM | 3 MTR | 1.2 | 5.450 | 1.820 | 27.3 | 5 |
108MM | 3 MTR | 2.5 | 22.290 | 7.430 | 44.6 | 2 |
Eddy-Current Test-Each tube shall be passed through an eddy-current testing unit adjusted to provide information on the suitability of the tube for the intended application. Testing shall follow the procedures of Practice E 243.
Each tube shall stand, without showing evidence of leakage, an internal hydrostatic pressure sufficient to subject the material to a fiber stress of 7000 psi [48 MPa] as determined by the following equation for thin hollow cylinders under tension. The tube need not be tested at a hydrostatic pressure of over 1000 psi [7.0 MPa] unless so specified.